CPVC Spigot Female Sprinkler Head Adapter | 1 in. x 1/2 in. Brass Thread | Spears FlameGuard™ | 4238-130

SKU:
51-SP-FSSA-BR-160800
Manufacturer Part Number:
4238-130
$8.82
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
51-SP-FSSA-BR-160800
Manufacturer Part Number:
4238-130
Manufacturer:
Spears™
Brand:
FlameGuard™
Material:
Chlorinated Polyvinyl Chloride (CPVC)
Fitting:
Head Adapter
Size:
1 in. x 1/2 in.
Size Detail:
1 in. x 1/2 in. Head Adapter
Thread Size:
1/2 in.
Thread Material:
Brass
Finish:
Orange
Rated Working Water Pressure:
175 PSI
Rated Working Temperature:
150F
UL Listed:
Yes
FM Approved:
Yes

CPVC Spigot Female Sprinkler Head Adapter | 1 in. x 1/2 in. Brass Thread | Spears FlameGuard™ | 4238-130 | Hero

CPVC Spigot Female Sprinkler Head Adapter | 1 in. x 1/2 in. Brass Thread | Spears FlameGuard™ | 4238-130 | Hero
CPVC Spigot Female Sprinkler Head Adapter | 1 in. x 1/2 in. Brass Thread | Spears FlameGuard™ | 4238-130 | Side
CPVC Spigot Female Sprinkler Head Adapter | 1 in. x 1/2 in. Brass Thread | Spears FlameGuard™ | 4238-130 | Outlet
CPVC Spigot Female Sprinkler Head Adapter | 1 in. x 1/2 in. Brass Thread | Spears FlameGuard™ | 4238-130 | Inlet
Play Button
Overview

CPVC Spigot Female Sprinkler Head Adapter — 1 in. x 1/2 in. Brass Thread — Spears FlameGuard™ — 4238-130

The Spears FlameGuard™ 1 in. x 1/2 in. spigot female sprinkler head adapter connects CPVC pipe to brass sprinkler heads in wet fire sprinkler systems. Constructed from fire-protection-grade CPVC, it offers high impact strength, corrosion resistance, and reliable performance. The brass female thread insert provides a durable and heat-resistant connection for sprinkler installation. The spigot end connects to a CPVC socket fitting using ASTM F493-approved solvent cement to form a watertight joint. UL Listed and FM Approved, this fitting complies with NFPA 13, NFPA 13R, and NFPA 13D. It is rated for 175 psi and up to 150°F, making it suitable for residential and light-hazard systems.

Follow Spears FlameGuard™ installation procedures for proper cleaning, cementing, and sprinkler head installation. Use a CPVC-compatible sealant and tighten carefully to the specified torque. The brass insert provides superior thread durability and prevents damage from heat or mechanical stress. This adapter delivers a corrosion-resistant, code-compliant, and UL/FM-approved connection between CPVC piping and brass sprinkler heads.