CPVC TorqueSafe™ Female Sprinkler Head Adapter | 3/4 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4235-101 G

SKU:
51-SP-FSA-TS-BR-120800
Manufacturer Part Number:
4235-101 G
$7.91
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
51-SP-FSA-TS-BR-120800
Manufacturer Part Number:
4235-101 G
Manufacturer:
Spears™
Brand:
FlameGuard™
Material:
Chlorinated Polyvinyl Chloride (CPVC)
Fitting:
Head Adapter
Size:
3/4 in. x 1/2 in.
Size Detail:
3/4 in. x 1/2 in. Head Adapter
Thread Size:
1/2 in.
Thread Material:
Brass
Finish:
Orange
Rated Working Water Pressure:
175 PSI
Rated Working Temperature:
150F
UL Listed:
Yes
FM Approved:
Yes

CPVC TorqueSafe™ Female Sprinkler Head Adapter | 3/4 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4235-101 G | Hero

CPVC TorqueSafe™ Female Sprinkler Head Adapter | 3/4 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4235-101 G | Hero
CPVC TorqueSafe™ Female Sprinkler Head Adapter | 3/4 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4235-101 G | Side
CPVC TorqueSafe™ Female Sprinkler Head Adapter | 3/4 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4235-101 G | Installed
CPVC TorqueSafe™ Female Sprinkler Head Adapter | 3/4 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4235-101 G | Outlet
CPVC TorqueSafe™ Female Sprinkler Head Adapter | 3/4 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4235-101 G | Inlet
Play Button
Overview

CPVC TorqueSafe™ Female Sprinkler Head Adapter — 3/4 in. x 1/2 in. Gasket Sealed Brass Thread — Spears FlameGuard™ — 4235-101 G

The Spears FlameGuard™ TorqueSafe™ 3/4 in. x 1/2 in. female sprinkler head adapter connects CPVC pipe to brass sprinkler heads in wet fire sprinkler systems. It features a brass insert with a gasket-sealed female thread that ensures a watertight and reusable connection. The TorqueSafe™ design includes a built-in stop to prevent overtightening and reduce stress on the CPVC body. Made from fire-protection-grade CPVC, it provides corrosion resistance and long-term durability. The socket end joins to CPVC pipe using ASTM F493-compliant solvent cement for a strong, leak-free bond. UL Listed and FM Approved, this fitting meets NFPA 13, NFPA 13R, and NFPA 13D standards, and is rated for 175 psi and 150°F maximum temperature.

Install following Spears FlameGuard™ instructions for pipe cleaning, solvent cementing, and sprinkler head assembly. Use a CPVC-approved sealant and follow torque specifications to maintain a secure seal. The gasket design provides consistent leak protection without damaging threads. This adapter offers a corrosion-resistant, UL/FM-approved connection between CPVC pipe and brass sprinkler heads for residential and light-hazard fire protection systems.