CPVC TorqueSafe™ Female Spigot Sprinkler Head Adapter | 1 in. x 1/2 in. Gasket Sealed Brass Insert Thread | Spears FlameGuard™ | 4238-130 G

SKU:
51-SP-FSSA-TS-BR-160800
Manufacturer Part Number:
4238-130 G
$8.42
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
51-SP-FSSA-TS-BR-160800
Manufacturer Part Number:
4238-130 G
Manufacturer:
Spears™
Brand:
FlameGuard™
Material:
Chlorinated Polyvinyl Chloride (CPVC)
Fitting:
Head Adapter
Size:
1 in. x 1/2 in.
Size Detail:
1 in. x 1/2 in. Head Adapter
Finish:
Orange
Rated Working Water Pressure:
175 PSI
Rated Working Temperature:
150F
UL Listed:
Yes
FM Approved:
Yes

CPVC TorqueSafe™ Female Spigot Sprinkler Head Adapter | 1 in. x 1/2 in. Gasket Sealed Brass Insert Thread | Spears FlameGuard™ | 4238-130 G

CPVC TorqueSafe™ Female Spigot Sprinkler Head Adapter | 1 in. x 1/2 in. Gasket Sealed Brass Insert Thread | Spears FlameGuard™ | 4238-130 G
CPVC TorqueSafe™ Female Spigot Sprinkler Head Adapter | 1 in. x 1/2 in. Gasket Sealed Brass Insert Thread | Spears FlameGuard™ | 4238-130 G
CPVC TorqueSafe™ Female Spigot Sprinkler Head Adapter | 1 in. x 1/2 in. Gasket Sealed Brass Insert Thread | Spears FlameGuard™ | 4238-130 G
CPVC TorqueSafe™ Female Spigot Sprinkler Head Adapter | 1 in. x 1/2 in. Gasket Sealed Brass Insert Thread | Spears FlameGuard™ | 4238-130 G
Play Button
Overview

CPVC TorqueSafe™ Female Spigot Sprinkler Head Adapter — 1 in. x 1/2 in. Gasket Sealed Brass Insert Thread — Spears FlameGuard™ — 4238-130 G

The Spears FlameGuard™ TorqueSafe™ 1 in. x 1/2 in. female spigot sprinkler head adapter connects CPVC pipe to brass sprinkler heads in wet fire sprinkler systems. This fitting includes a brass insert with a gasket-sealed thread to ensure a watertight, reusable connection. The TorqueSafe™ feature prevents overtightening, protecting the CPVC body from stress or cracking. Made from fire-protection-grade CPVC, it offers corrosion resistance, heat tolerance, and long-term reliability. The spigot end connects to CPVC fittings using ASTM F493-approved solvent cement for a strong, leak-free bond. UL Listed and FM Approved, it meets NFPA 13, NFPA 13R, and NFPA 13D standards. It is rated for 175 psi and a maximum service temperature of 150°F.

Install following Spears FlameGuard™ recommendations for cleaning, cementing, and sprinkler head assembly. Use CPVC-approved thread sealant and follow torque limits. The gasket seal ensures leak protection and long-lasting performance while reducing installation stress. This adapter provides a corrosion-resistant, code-compliant, and UL/FM-approved solution for connecting CPVC piping to sprinkler heads in wet fire sprinkler systems.