CPVC TorqueSafe™ 90 Degree Sprinkler Head Elbow | 1 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4207-130 G

SKU:
51-SP-90HE-TS-BR-160800
Manufacturer Part Number:
4207-130 G
$11.48
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
51-SP-90HE-TS-BR-160800
Manufacturer Part Number:
4207-130 G
Manufacturer:
Spears™
Brand:
FlameGuard™
Material:
Chlorinated Polyvinyl Chloride (CPVC)
Fitting:
Head Elbow
Size:
1 in. x 1/2 in.
Size Detail:
1 in. x 1/2 in. Head Elbow
Thread Size:
1/2 in.
Thread Material:
Brass
Finish:
Orange
Rated Working Water Pressure:
175 PSI
Rated Working Temperature:
150F
UL Listed:
Yes
FM Approved:
Yes

CPVC TorqueSafe™ 90 Degree Sprinkler Head Elbow | 1 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4207-130 G

CPVC TorqueSafe™ 90 Degree Sprinkler Head Elbow | 1 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4207-130 G
CPVC TorqueSafe™ 90 Degree Sprinkler Head Elbow | 1 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4207-130 G
CPVC TorqueSafe™ 90 Degree Sprinkler Head Elbow | 1 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4207-130 G
CPVC TorqueSafe™ 90 Degree Sprinkler Head Elbow | 1 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4207-130 G
Play Button
Overview

CPVC TorqueSafe™ 90 Degree Sprinkler Head Elbow — 1 in. x 1/2 in. Gasket Sealed Brass Thread — Spears FlameGuard™ — 4207-130 G

The Spears FlameGuard™ TorqueSafe™ 1 in. x 1/2 in. 90° sprinkler head elbow is designed to connect CPVC piping to brass sprinkler heads in wet fire sprinkler systems. The fitting features a brass insert with a gasket-sealed female thread for a watertight and reusable joint. The TorqueSafe™ design includes a built-in stop to prevent overtightening, helping protect the CPVC body from stress. The socket end joins to CPVC pipe using ASTM F493-approved solvent cement, forming a secure, leak-free bond. UL Listed and FM Approved, this fitting meets NFPA 13, NFPA 13R, and NFPA 13D installation standards. It is rated for 175 psi and a maximum temperature of 150°F.

Follow Spears FlameGuard™ installation instructions for cleaning, cementing, and tightening. Use CPVC-approved thread sealant and avoid exceeding recommended torque. The gasket-sealed brass threads ensure a leak-free, corrosion-resistant connection that can be reused if needed. This 90° elbow provides a durable, code-compliant solution for residential and light-hazard CPVC wet fire sprinkler systems meeting UL and FM approval requirements.