CPVC TorqueSafe™ Sprinkler Head Tee | 1 in. x 1/2 in. x 1 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4203-122 G

SKU:
51-SP-HT-TS-BR-160816
Manufacturer Part Number:
4203-122 G
$10.03
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
51-SP-HT-TS-BR-160816
Manufacturer Part Number:
4203-122 G
Manufacturer:
Spears™
Brand:
FlameGuard™
Material:
Chlorinated Polyvinyl Chloride (CPVC)
Fitting:
Head Tee
Size:
1 in. x 1/2 in. x 1 in.
Size Detail:
1 in. x 1/2 in. x 1 in. Head Tee
Thread Size:
1 in.
Thread Material:
Brass
Finish:
Orange
Rated Working Water Pressure:
175 PSI
Rated Working Temperature:
150F
UL Listed:
Yes
FM Approved:
Yes

CPVC TorqueSafe™ Sprinkler Head Tee | 1 in. x 1/2 in. x 1 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4203-122 G

CPVC TorqueSafe™ Sprinkler Head Tee | 1 in. x 1/2 in. x 1 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4203-122 G
CPVC TorqueSafe™ Sprinkler Head Tee | 1 in. x 1/2 in. x 1 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4203-122 G
CPVC TorqueSafe™ Sprinkler Head Tee | 1 in. x 1/2 in. x 1 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4203-122 G
CPVC TorqueSafe™ Sprinkler Head Tee | 1 in. x 1/2 in. x 1 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4203-122 G
Play Button
Overview

CPVC TorqueSafe™ Sprinkler Head Tee — 1 in. x 1/2 in. x 1 in. Gasket Sealed Brass Thread — Spears FlameGuard™ — 4203-122 G

The Spears FlameGuard™ TorqueSafe™ 1 in. x 1/2 in. x 1 in. sprinkler head tee connects CPVC piping to brass sprinkler heads in wet fire sprinkler systems. It features a brass insert with a gasket-sealed female thread for a watertight and reusable connection. The TorqueSafe™ design includes a built-in stop to prevent overtightening and reduce stress on the CPVC body. The fire-protection-grade CPVC material provides durability and corrosion resistance in long-term service. Socket ends connect to CPVC pipe using ASTM F493-compliant solvent cement for a leak-free joint. UL Listed and FM Approved, this fitting meets NFPA 13, NFPA 13R, and NFPA 13D standards. It is rated for 175 psi and a maximum service temperature of 150°F.

Follow Spears FlameGuard™ installation instructions for cleaning, solvent cementing, and sprinkler assembly. Use CPVC-compatible thread sealant and adhere to recommended torque limits. The gasket seal ensures leak protection and simplifies assembly while preventing over-torque damage. This sprinkler head tee provides a code-compliant, corrosion-resistant, and UL/FM-approved connection for reliable CPVC wet fire sprinkler system installations.