CPVC TorqueSafe™ 90 Degree Sprinkler Head Elbow | 3/4 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4207-101 G

SKU:
51-SP-90HE-TS-BR-120800
Manufacturer Part Number:
4207-101 G
$8.79
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
51-SP-90HE-TS-BR-120800
Manufacturer Part Number:
4207-101 G
Manufacturer:
Spears™
Brand:
FlameGuard™
Material:
Chlorinated Polyvinyl Chloride (CPVC)
Fitting:
Head Elbow
Size:
3/4 in. x 1/2 in.
Size Detail:
3/4 in. x 1/2 in. Head Elbow
Thread Size:
1/2 in.
Thread Material:
Brass
Finish:
Orange
Rated Working Water Pressure:
175 PSI
Rated Working Temperature:
150F
UL Listed:
Yes
FM Approved:
Yes

CPVC TorqueSafe™ 90 Degree Sprinkler Head Elbow | 3/4 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4207-101 G

CPVC TorqueSafe™ 90 Degree Sprinkler Head Elbow | 3/4 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4207-101 G
CPVC TorqueSafe™ 90 Degree Sprinkler Head Elbow | 3/4 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4207-101 G
CPVC TorqueSafe™ 90 Degree Sprinkler Head Elbow | 3/4 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4207-101 G
CPVC TorqueSafe™ 90 Degree Sprinkler Head Elbow | 3/4 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4207-101 G
Play Button
Overview

CPVC TorqueSafe™ 90 Degree Sprinkler Head Elbow — 3/4 in. x 1/2 in. Gasket Sealed Brass Thread — Spears FlameGuard™ — 4207-101 G

The Spears FlameGuard™ TorqueSafe™ 3/4 in. x 1/2 in. 90° sprinkler head elbow connects CPVC piping to brass sprinkler heads at a right angle in wet fire sprinkler systems. The fitting includes a brass insert with a gasket-sealed female thread for a watertight, reusable joint. The TorqueSafe™ design prevents overtightening and reduces stress on the CPVC body. Made from fire-protection-grade CPVC, it offers corrosion resistance and dependable long-term performance. The socket end connects to CPVC pipe using ASTM F493-compliant solvent cement for a permanent, leak-free seal. UL Listed and FM Approved, this fitting meets NFPA 13, NFPA 13R, and NFPA 13D standards. It is rated for 175 psi and a maximum temperature of 150°F.

Install per Spears FlameGuard™ guidelines for pipe cleaning, solvent cementing, and sprinkler head tightening. Use CPVC-safe thread sealant and do not exceed specified torque limits. The gasket-sealed brass threads ensure a consistent seal while reducing the risk of cracking or leaks. This elbow fitting provides a corrosion-resistant, code-compliant, and UL/FM-approved connection for CPVC wet fire sprinkler systems in residential and light-hazard environments.