Viking® VK530 Upright Sprinkler | SR | 11.2K | Black | 286F | 09679MG/B

SKU:
VK530BL286
Manufacturer Part Number:
09679MG/B

No reviews yet Write a Review
$39.00

Viking® VK530 Upright Sprinkler | SR | 11.2K | Black | 286F | 09679MG/B | QRFS | Hero

Viking® VK530 Upright Sprinkler | SR | 11.2K | Black | 286F | 09679MG/B | QRFS | Hero
Viking® VK530 Upright Sprinkler | SR | 11.2K | Black | 286F | 09679MG/B | QRFS | Side
Viking® VK530 Upright Sprinkler | SR | 11.2K | Black | 286F | 09679MG/B | QRFS | Deflector

  • Buy 50 - 99 and get 3% off
  • Buy 100 or above and get 7% off

Frequently Bought Together:

Viking® VK530 Upright Sprinkler | SR | 11.2K | Black | 286F | 09679MG/B | QRFS | Hero
Inc. Tax
Ex. Tax
Overview

Viking ELO Standard Response Upright Storage (VK530) Fire Sprinkler Head

This Viking ELO (Extra-Large Orifice) SR Upright Fire Sprinkler (Storage-Density/Area) features a glass bulb activating at 286F (141C) with an 11.2 K-Factor, and 3/4 in. NPT threads. Each upright head features a brass frame and brass deflector. The Sprinkler Identification Number (SIN) is VK530. This is a standard response, standard coverage sprinkler with a maximum working water pressure of 175 PSI.

The VK530 Upright Storage sprinkler delivers effective, affordable defense against fire in hazard occupancies up to and including Extra-Hazard Group II (UL). Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 286F (141C), drenching the area surrounding a fire to keep it in its place of origin.

Viking Upright SR Fire Sprinkler ELO (VK530) Sprinkler Head Listings and Approvals

Each ELO upright sprinkler is made by Viking, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this fire sprinkler head maintains listings and approvals from cULus (Category VNIV), and is FM Approved (Class 2009). Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

Standard Response Extra-Large Orifice Upright Sprinkler VK530 is cULus Listed for installation in accordance with the latest edition of NFPA 13 for standard spray upright sprinklers. Designed for use in hazard occupancies up to and including Extra-Hazard Group II with a minimum operating pressure of 7 psi (0.5 bar). Sprinkler VK530 is also cULus Listed for use in High-Piled Storage Occupancies as defined in NFPA 13 with a minimum operating pressure of 7 psi (0.5 bar). The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray upright sprinklers must be followed.

Standard Response Extra-Large Orifice Upright Sprinkler VK530 is FM Approved for use as a standard response upright Storage sprinkler as indicated in the FM Approval Guide in the datasheet.

This upright storage sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) UL, FM and connects to wet piping systems.

Viking ELO (VK530) Upright Storage Sprinkler Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 3/4 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 20 ft-lb (27.1 N-m). Refer to the data sheet for additional storage and installation information.

This upright extra-large orifice sprinkler features a black finish and a 286F (141C) temperature. Available finish options include Brass, Chrome, White, and Black. White Polyester Painted (White), and Flat Black Polyester Painted (Black) are UL Listed as corrosion resistant. Temperature options include 155F (68C), 175F (79C), 200F (93C), and 286F (141C). Finish and temperature combinations available in the “Options” section at the top of this product page.

The VK530 listed accessories include the approved Viking Wrench (part no. 05118CW/B). Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Specifications
QRFS SKU:
VK530BL286
Manufacturer Part Number:
09679MG/B
Manufacturer:
Viking
SIN:
VK530
Model:
ELO
Head Type:
Upright
Finish:
Black
Finish Detail:
Black Polyester
Size:
3/4 in.
Size Detail:
3/4 in. NPT Sprinkler
K Factor:
11.2K
Response Type:
Standard Response (SR)
Temperature:
286F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
Yes
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
No
Maximum Working Water Pressure:
175 PSI
Length:
1.75 in. (44.45 mm)
Width:
1.75 in. (44.45 mm)
Height:
2.31 in. (58.67 mm)
Weight:
0.3 lb. (0.14 kg)
Available Box/Pack Quantity:
50
Reviews
No reviews yet

Customers Also Viewed