Black Iron Pipe Nipple | 1 in. NPT | Close

SKU:
100BNIPC
Manufacturer Part Number:
1CBNIP

No reviews yet Write a Review
$1.25
Black Iron Pipe Nipple | 1 in. (25 mm) NPT | Close | 1CBNIP
Black Iron Pipe Nipple | 1 in. (25 mm) NPT | Close | 1CBNIP
Black Iron Pipe Nipple | 1 in. (25 mm) NPT | Close | 1CBNIP | Inside View
Side View of Black Iron Pipe Nipple | 1 in. (25 mm) NPT | Close | 1CBNIP
Perspective View of Black Iron Pipe Nipple | 1 in. (25 mm) NPT | Close | 1CBNIP

  • Buy 10 - 99 and get 5% off
  • Buy 100 or above and get 10% off

Frequently Bought Together:

Black Iron Pipe Nipple | 1 in. (25 mm) NPT | Close | 1CBNIP
Inc. Tax
Ex. Tax

Overview

1 in. (25mm) NPT x Close Black Iron Pipe Nipple, commonly used with fire sprinkler pipes, connects two female pipes using two male-threaded pipe ends. Made by Anvil International, a New Hampshire-based manufacturer with over 150 years in the piping industry, these carbon steel threaded pipe nipples are able to withstand temperatures of up to 392F (200C).

These 1 in. x Close NPT nipples are frequently used in valve trim applications. Often, contractors use these nipples to connect 2 in. angle valves to riser check valves installed in a âshotgunâ configuration. Using these valves and nipples, fire professionals can quickly and economically attach a drain valve to an existing check valve.

Will this item fit my fire sprinkler or plumbing system?

A close nipple implies that there is no unthreaded area on the pipe , both ends of male threading run into each other, rather than be separated by a section of unthreaded pipe. This can make for a tougher time if the nipple or attached pipe needs to be removed, but it eliminates any gap between the two connecting pipes, reducing the space needed for installation.

This black iron nipple is designed to install between two pipes with 1 in. female National Pipe Thread (NPT) and has only the minimum length required to engage with the ends of the connecting pipes. In action, this nipple is often found as a connector within an alarm or riser check valve system to provide easy access for inspection. Additionally, in cases of repairing piping, systems transporting gas and oil in urban and rural areas, and any other industry needing to connect, terminate, control, or change the direction of flow, the black iron nipple is an ideal solution.

Other available sizes for black iron pipe nipples include:

Contractors installing a shotgun riser check valve may also want to view our selection of 1/4 in. NPT square head plugs, which close off the ends of three-way valves controlling the flow of water to pressure gauges.

Is black steel pipe safe to use with my fire protection piping?

Strength, durability, and heat-resistant characteristics make black steel pipe a common choice in fire sprinkler systems. Where moisture and oxygen mix, black steel is generally more cost-effective, corrosion-resistant, and safer than galvanized alternatives.

However, black steel can be susceptible to corrosion, particularly in dry-pipe systems, where condensation or leftover water can combine with air to facilitate rapid rusting. Replacing pressurized air with nitrogen can extend the life of black steel in dry systems, as can filling wet-pipe systems with nitrogen before adding water. Black steel should not be mixed with galvanized steel, as it may accelerate corrosion in the piping system.

Specifications

Reviews

No reviews yet

Customers Also Viewed

Black Iron Pipe Nipple | 2 in. (51 mm) NPT | Close | 2CBNIP Black Iron Pipe Nipple | 2 in. (51 mm) NPT | Close | 2CBNIP

Black Iron Pipe Nipple | 2 in. NPT | Close

SKU : 200BNIPC

$2.75
2 in. (51 mm) NPT x Close Black Iron Pipe Nipple, commonly used with fire sprinkler pipes, connects two female pipes using two male-threaded pipe ends. Made by Anvil International, a New...
1 1/4 in. CPVC Slip Cap Inside of 1-1/4 in. CPVC Slip Cap

CPVC Cap | Slip | 1-1/4 in.

SKU : TCPVCCA4

$1.99
1 1/4" CPVC Slip Cap closes off CPVC pipes used in NFPA 13, NFPA 13D, and NFPA 13R fire sprinkler systems. This UL-listed and FM-approved fitting is made with heat-resistant thermoplastic CPVC. Made...