CPVC SofTorque™ Spigot Female Adapter | 1 in. x 1/2 in. Gasket Sealed Reinforced Plastic Thread | Spears FlameGuard™ | 4278-130GSR

SKU:
51-SP-FSPA-ST-PL-160800
Manufacturer Part Number:
4278-130GSR
$18.73
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
51-SP-FSPA-ST-PL-160800
Manufacturer Part Number:
4278-130GSR
Manufacturer:
Spears™
Brand:
FlameGuard™
Material:
Chlorinated Polyvinyl Chloride (CPVC)
Fitting:
Adapter
Size:
1 in. x 1/2 in.
Size Detail:
1 in. x 1/2 in. Adapter
Thread Size:
1/2 in.
Thread Material:
Reinforced Plastic
Finish:
Orange
Rated Working Water Pressure:
175 PSI
Rated Working Temperature:
150F
UL Listed:
Yes
FM Approved:
Yes

CPVC SofTorque™ Spigot Female Adapter | 1 in. x 1/2 in. Gasket Sealed Reinforced Plastic Thread | Spears FlameGuard™ | 4278-130GSR

CPVC SofTorque™ Spigot Female Adapter | 1 in. x 1/2 in. Gasket Sealed Reinforced Plastic Thread | Spears FlameGuard™ | 4278-130GSR
CPVC SofTorque™ Spigot Female Adapter | 1 in. x 1/2 in. Gasket Sealed Reinforced Plastic Thread | Spears FlameGuard™ | 4278-130GSR
CPVC SofTorque™ Spigot Female Adapter | 1 in. x 1/2 in. Gasket Sealed Reinforced Plastic Thread | Spears FlameGuard™ | 4278-130GSR
CPVC SofTorque™ Spigot Female Adapter | 1 in. x 1/2 in. Gasket Sealed Reinforced Plastic Thread | Spears FlameGuard™ | 4278-130GSR
Play Button
Overview

CPVC SofTorque™ Spigot Female Adapter — 1 in. x 1/2 in. Gasket Sealed Reinforced Plastic Thread — Spears FlameGuard™ — 4278-130GSR

The Spears FlameGuard™ SofTorque™ 1 in. x 1/2 in. spigot female adapter provides a connection between CPVC piping and sprinkler heads in wet fire sprinkler systems. This adapter features a gasket-sealed reinforced plastic thread for a watertight, reusable seal. The SofTorque™ design limits overtightening to prevent stress and cracking in the fitting body. Made from fire-protection-grade CPVC, it provides high strength, corrosion resistance, and long-term reliability. The spigot end connects to CPVC socket fittings with ASTM F493-compliant solvent cement, forming a watertight joint. UL Listed and FM Approved, this adapter meets NFPA 13, NFPA 13R, and NFPA 13D requirements. It is rated for 175 psi and a maximum service temperature of 150°F.

Follow Spears FlameGuard™ instructions for cleaning, solvent cementing, and assembly. Apply CPVC-safe thread sealant and tighten only to specified torque limits. The gasket ensures consistent sealing and helps prevent leaks or thread damage. This fitting provides a corrosion-resistant, code-compliant, and UL/FM-approved connection for CPVC wet fire sprinkler systems used in residential and light-hazard applications.