3/4" (19.05 mm) Slip x 1/2" (12.7 mm) FNPT CPVC 90-Degree Elbow Adapter

SKU
TCPVCT9E21
3/4" Slip x 1/2" FNPT CPVC 90-Degree Elbow Adapter joins CPVC to NPT-threaded fire sprinkler heads in NFPA 13, NFPA 13D, and NFPA 13R fire sprinkler systems. This UL & FM-approved elbow is made from CPVC with a brass FNPT insert. Made in the USA!
$6.95
SKUDesignMaterialSocket Diameter
TCPVCT9E2190-Degree Elbow AdapterChlorinated Polyvinyl Chloride (CPVC) with Threaded Brass Insert3/4" (19.05 mm) Slip
Brass Insert DiameterWorking PressureTemperature RangeListings
1/2" (12.7 mm) FNPT175 PSI at 150F (65C)35F to 150F (2C to 65C)UL-Listed and FM-Approved. UL listed for Light Hazard Occupancies (NFPA 13) and Residential & Home Fire Sprinkler Systems (NFPA 13D, NFPA 13R)
Thermafit Industries Part NumberAvailability
CP90-112BUsually Ships Within 48 Hours

Product Description

3/4" Slip x 1/2" FNPT CPVC 90-Degree Elbow Adapter joins corrosion-resistant CPVC thermoplastic pipe to metallic pipe with National Pipe Thread (NPT). This 90-degree CPVC adapter features a 3/4" (19.05 mm) slip end and a threaded brass 1/2" (12.7 mm) FNPT end designed for connection to fire sprinkler heads.

Each 3/4" Slip x 1/2" FNPT CPVC 90-Degree Elbow Adapter is made in the USA by Thermafit Industries, Inc., a California-based manufacturer of plumbing and fire sprinkler pipe fittings. This adapter has a working pressure rating of 175 PSI at 150F (65C) and is suitable for installation in NFPA 13, NFPA 13D, and NFPA 13R systems where allowed by state and local law.

3/4" Slip x 1/2" FNPT CPVC 90-Degree Elbow Adapter is intended for use in light hazard NFPA 13 occupancies, residential NFPA 13R occupancies, and home fire sprinkler systems in accordance with NFPA 13D. This product is UL-listed for use in wet-pipe automatic fire sprinkler systems in combination with UL-listed CPVC products.

3/4" Slip x 1/2" FNPT CPVC 90-Degree Elbow Adapter is backed by Thermafit's ten-year warranty from the date of shipment. To find Thermafit-approved CPVC glue, click here. Consult Thermafit's installation manual for minimum curing times, a full list of compatible adhesives, and friction loss allowances. Not suitable for outdoor installation.

Dimensions

CPVC Adapter Dimensions

  • A: 1.058"
  • B: 1.046"
  • C: 0.730" (Schedule 40) or 1.460" (Schedule 80)
  • F: 1.490"

Technical Documents

Click here to view the manual for this 3/4" Slip x 1/2" FNPT CPVC 90-Degree Elbow Adapter.