Need a replacement fire sprinkler system part? Our trained staff will help you find the right part, the first time. Call us at 888-361-6662.

Black Iron Pipe Nipple | 1/4″ NPT | 3″ (76 mm) Length | 143BNIP

SKU
025BNIP300
This black iron nipple features a 1/4″ (6mm) male threading at each end of a 3″ (76mm) nipple to connect two female pipes. Made from carbon steel and designed for temperatures up to 392F (200C). Ideal for connections to three-way valves on “shotgun” riser check valves.
$1.50
SKU Material Finish & Coating
025BNIP300 Carbon Steel Alloy Black & Galvanized
Pipe Size Length Thread Type
1/4″ (6mm) 3″ (76mm) Male National Pipe Thread (MNPT)
Maximum Temperature Approvals & Listings Anvil Part No.
392F (200C) ASTM A733, ASTM A53 143BNIP
Availability
Usually Ships Within 48 Hours

1/4″ (6 mm) x 3″ (76 mm) NPT Black Iron Pipe Nipple

1/4″ (6 mm) x 3″ (76 mm) NPT Black Iron Pipe Nipple, commonly used with fire sprinkler pipes, connects two female pipes using two male-threaded pipe ends. Made by Anvil International, a New Hampshire-based manufacturer with over 150 years in the piping industry, these carbon steel threaded pipe nipples are able to withstand temperatures of up to 392F (200C).

These 1/4″ x 3″ NPT nipples are frequently used in valve trim applications. Often, contractors use these nipples to connect three-way valves to riser check valves installed in a “shotgun” configuration. Using these valves and nipples, fire professionals can quickly and economically attach gauges used to monitor supply- and system-side pressure in fire sprinkler systems.

Will this item fit my fire sprinkler or plumbing system?

This black iron nipple is designed to install between two pipes with 1/4″ female National Pipe Thread (NPT) and has a total length of 3″ (76mm). This fitting is often used to connect a check valve and a 3-way valve, which in turn connects to a gauge within a check valve system. When water exits the check valve through the first nipple, either before or after the clapper, it will also enter the gauge through the second nipple to give inspectors easy access to pressure readings.

Other available sizes for black iron pipe nipples include:

Contractors installing a shotgun riser check valve may also want to view our selection of 1/4″ NPT square head plugs, which close off the ends of three-way valves controlling the flow of water to pressure gauges.

Is black steel pipe safe to use with my fire protection piping?

Strength, durability, and heat-resistant characteristics make black steel pipe a common choice in fire sprinkler systems. Where moisture and oxygen mix, black steel is generally more cost-effective, corrosion-resistant, and safer than galvanized alternatives.

However, black steel can be susceptible to corrosion, particularly in dry-pipe systems, where condensation or leftover water can combine with air to facilitate rapid rusting. Replacing pressurized air with nitrogen can extend the life of black steel in dry systems, as can filling wet-pipe systems with nitrogen before adding water. Black steel should not be mixed with galvanized steel, as it may accelerate corrosion in the piping system.

Write Your Own Review
You're reviewing:Black Iron Pipe Nipple | 1/4″ NPT | 3″ (76 mm) Length | 143BNIP
Your Rating