Need a replacement fire sprinkler system part? Our trained staff will help you find the right part, the first time. Call us at 888-361-6662.

Tyco Escutcheon | Style 40 | Recessed | 3/4 in. Sprinkler | White | 56-700-4-010

SKU
TY075RES40WH
With 3/4″ of adjustment—the maximum available in any Tyco-brand escutcheon—and a 2-7/8″ outer ring, Tyco’s White Style 40 Recessed Fire Sprinkler Escutcheon covers the gap between a sprinkler head and the ceiling. Combine this white escutcheon with a variety of Tyco, Central, Gem, and Star fire sprinklers to form a listed sprinkler assembly.
$4.23
SKU Finish Thread
TY075RES40WH White 3/4″ (19mm) NPT
Adjustment Outer Cup Diameter Depth of Outer Cup
3/4″ (19 mm) 2-7/8″ (73 mm) 1 1/8″ (29 mm)
Tyco Part No. Approvals & Listings Availability
56-700-4-010 UL, C-UL, FM* Usually Ships Within 48 Hours

Tyco White Style 40 Recessed Escutcheon for 3/4″ NPT Fire Sprinklers

Tyco’s White Style 40 Recessed Fire Sprinkler Escutcheon covers the gap between a sprinkler head and the ceiling, providing a smooth, aesthetically pleasing appearance. Tyco’s Style 40 escutcheon combines with select sprinkler heads to form a listed sprinkler assembly. These assemblies prevent smoke and heat from bypassing the heat-sensitive components of a fire sprinkler, helping them to activate at the proper time.

This recessed, two-piece escutcheon plate is tailored to provide a low-profile and decorative installation for 3/4″ NPT recessed pendent and horizontal sidewall sprinklers manufactured by Tyco and Central. The Tyco Style 40 Fire Sprinkler Escutcheon also offers 3/4″ of adjustment—the most of any Tyco-brand escutcheon.

Will this escutcheon fit my sprinkler system?

Escutcheons are available in several finishes, sizes, and styles. The Tyco Style 40 Recessed Escutcheon is available from QRFS in a chrome or white finish, and may be installed as part of a listed sprinkler assembly with Tyco-brand sprinklers having the following sprinkler identification numbers (SINs):

  • TY3231
  • TY3251
  • TY4131
  • TY4151
  • TY4231
  • TY4232
  • TY4251
  • TY4332
  • TY4931
  • TY4951
  • TY5237
  • TY6237

In addition, these escutcheons also replace Central 4211 escutcheons, Gem F700 escutcheons (for 3/4″ fire sprinklers), and Star 2088 escutcheons.

Installing a Style 40 escutcheon with either of these sprinklers allows those sprinklers to retain their listings and approvals from UL, cUL, and FM.

More Information
Escutcheon Type Recessed
Escutcheon Fits Sprinkler Connection Size 3/4"
Escutcheon Finish White
Escutcheon Retrofit No
Escutcheon Adjustable Yes
Escutcheon Adjustment 3/4"
Write Your Own Review
You're reviewing:Tyco Escutcheon | Style 40 | Recessed | 3/4 in. Sprinkler | White | 56-700-4-010
Your Rating