QRFS.com is open and fulfilling orders. Read our Emergency Preparedness Guide.

Tyco Residential Fire Sprinkler 4.9K Brass Pendent 155F | TY2234

SKU
TY2234BR155
Tyco TY2234 Residential Fast Response Brass Pendent Fire Sprinkler activates at 155F (68C) to defend light hazard residential occupancies against fire. This UL-listed fire sprinkler features a 4.9K orifice and a 1/2" (12.7 mm) NPT connection.
$14.95
  • Buy 50 for $13.90 each and save 7%
  • Buy 100 for $13.16 each and save 12%
  • Buy 500 for $12.41 each and save 17%
Part NumberConstructionConnectionOrifice
TY2234BR155Brass Finish, Bronze Frame, And Bronze Deflector1/2" (12.7 mm) NPT4.9K
Temperature RatingSprinkler WrenchMaximum Working PressureApprovals and Listings
155F (68C)Wrench - Tyco W-Type 6175 PSI (12.1 BAR)UL (wet & dry pipe), C-UL (dry pipe only), certified to all requirements of NSF/ANSI 61
Availability
Usually ships within 48 hours

Product Description

Tyco TY2234 Residential Fast Response Brass Pendent Fire Sprinkler delivers decorative, competitively-priced defense against fire in light hazard residential occupancies such as homes, apartments, dormitories, and hotels. Using a heat-activated 3mm glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), controlling residential fires and facilitating the safe evacuation and escape of a building's occupants.

The Tyco Model TY2234 has a 4.9 K-Factor and installs with 1/2" (12.7 mm) National Pipe Thread (NPT), used in fire sprinkler systems throughout the United States. This Residential Fast Response Fire Sprinkler features a brass finish, brass frame, bronze compression screw, bronze deflector, and a beryllium-nickel sealing assembly with PTFE.

This 155F (68C) temperature rating strikes a balance between a fire sprinkler that activates too soon, causing accidental discharge, and too late. 155F (68C) Residential Fast Response Fire Sprinklers can be installed to wet and dry pipe fire sprinkler systems, and are preferred for use in one and two-family dwellings, apartments, duplexes, and boarding houses. The Tyco Model TY2234 is also a suitable choice for installation in many college dormitories, condominiums, and nursing homes.

With a maximum working pressure of 175 PSI (12.1 BAR), this pendent sprinkler hangs from above-ceiling piping and may be installed and used in accordance with NFPA 13, NFPA 13R, NFPA 13D and local fire code. Each Model TY2234 sprinkler is made by Tyco, a global manufacturer with more than a half-century in the fire protection industry.

This product is UL-listed, and appropriate for use in fire protection systems when accepted by the authority having jurisdiction. In accordance with NFPA 13, a higher temperature rating may be required when installing a residential fast response fire sprinkler in or near heat sources, unventilated spaces, uncovered steam mains, or uninsulated rooftops.

Technical Documents

Click here to view the data sheet for the Tyco TY2234 Residential Fast Response Brass Pendent Fire Sprinkler.

Write Your Own Review
You're reviewing:Tyco Residential Fire Sprinkler 4.9K Brass Pendent 155F | TY2234
Your Rating