Need help finding the right replacement part for your fire protection system? Call QRFS at 888-361-6662.

Victaulic Residential Fire Sprinkler 4.9K Chrome Pendent 155F | V2740

SKU
V2740CH155
Victaulic V2740 Residential Fast Response Chrome Pendent Fire Sprinkler activates at 155F (68C) to defend ordinary hazard residential occupancies against fire. This UL-listed fire sprinkler features a 4.9K orifice and a 1/2" (12.7 mm) NPT connection.
$10.99
  • Buy 50 for $10.22 each and save 7%
  • Buy 100 for $9.67 each and save 12%
  • Buy 500 for $9.12 each and save 17%
Part NumberConstructionConnectionOrifice
V2740CH155Chrome Finish, Die-Cast Brass Frame, And Bronze Deflector1/2" (12.7 mm) NPT4.9K
Temperature RatingSprinkler WrenchMaximum Working PressureApprovals and Listings
155F (68C)Open-End Fire Sprinkler Wrench - Victaulic V27175 PSI (12.1 BAR)cULus
Availability
Usually ships within 48 hours

Product Description

Victaulic V2740 Residential Fast Response Chrome Pendent Fire Sprinkler delivers reliable and easily-installed protection against fire in ordinary hazard residential occupancies such as homes, apartments, dormitories, and hotels. Using a heat-activated 3mm glass bulb, this automatic fire sprinkler activates when the surrounding air reaches 155F (68C), lowering ambient temperatures to reduce flashover and facilitate safe escape.

The Victaulic Model V2740 has a 4.9 K-Factor and installs with 1/2" (12.7 mm) National Pipe Thread (NPT), used in fire sprinkler systems throughout the United States. This Residential Fast Response Fire Sprinkler features a chrome finish, die-cast brass frame, bronze load screw, bronze deflector, a bronze pip cap, and a PTFE-taped seal. The frame is cast with a hex-shaped wrench boss to make installation and tightening from many angles easy.

This 155F (68C) temperature rating strikes a balance between a fire sprinkler that activates too soon, causing accidental discharge, and too late. 155F (68C) Residential Fast Response Fire Sprinklers are preferred for use in theaters, restaurants, and other gathering spaces where human safety is the first priority. The Victaulic Model V2740 is also perfect for use in animal shelters, agricultural and food processing facilities, and fairgrounds.

With a maximum working pressure of 175 PSI (12.1 BAR), this pendent sprinkler mounts to ceiling pipes and may be installed and used in accordance with NFPA 13, NFPA 13R, NFPA 13D and local fire code. Each Model V2740 sprinkler is made by Victaulic, a piping-industry manufacturer and trusted producer of fire protection products since 1919.

This product is UL-listed, and appropriate for use in fire protection systems when accepted by the authority having jurisdiction. In accordance with NFPA 13, a higher temperature rating may be required when installing a residential fast response fire sprinkler in or near heat sources, unventilated spaces, uncovered steam mains, or uninsulated rooftops.

Technical Documents

Click here to view the data sheet for the Victaulic V2740 Residential Fast Response Chrome Pendent Fire Sprinkler.

Write Your Own Review
You're reviewing:Victaulic Residential Fire Sprinkler 4.9K Chrome Pendent 155F | V2740
Your Rating